Fancoil repair

Despite the high reliability of climate systems, nothing lasts forever. Sooner or later anticipated events requiring (often urgent) application. Excluding the complete rejection of the door closer and preliminary signs:

  • rare dysfunction;
  • loss of accuracy in maintaining air parameters;
  • unnatural noises and smells;
  • drops, wet spots, mold;
  • decrease in work efficiency (unfortunately, it can be detected only with constant monitoring of modes and power consumption).

Even the personnel of industrial enterprises (not to mention the users of domestic and office premises), as a rule, do not have the necessary skills, tools, measuring instruments, spare parts and materials for the correct diagnosis and repair of fan coil units.

 Mistakes in independent search for a failed component and selection of its replacement, violations of repair technology and simply irrational operations can negate the savings on outsourcing. It is still more profitable to attract a specialized company, such as ours.

Common Causes and Troubleshooting

Basically, fan coil units experience the same problems as in any equipment:

  • Breakage (for example, due to vibration) of power or communication cables (in systems with wired control). Sometimes it will be necessary to replace the entire wiring section, but the reliability after repair may be higher than the original one.
  • Failure of the electric motor (breakage or short circuit of the windings, wear or jamming of the bearings). It is more rational to replace it with a new one, the main thing is that it is exactly suitable for both electrical and mechanical characteristics.
  • Violation of the functions of control or protective automation. For convenience and speed, as a rule, the entire electronic unit is changed, and notисправный может быть восстановлен позже в лабораторных условиях. 

Etc. But there are specific problems that are specific to the devices of this group:

  • Clogging of the air fins of the heat exchanger with dust. A very common situation, leading at first not to a complete malfunction, but only to a decrease in the efficiency of the fan coil unit, an increase in energy consumption. It is eliminated by ordinary cleaning, which, strictly speaking, should be carried out during routine maintenance. Similarly, in the order of current operation, filters are replaced.
  • Destruction or deformation (due to aging, manufacturing defects or ingress of a solid object) of the fan impeller. Usually it is enough to replace the impeller itself, without even dismantling the engine, provided that the selection is exactly identical. If only the dimensions and landing coincide, but the width (shape, angle of attack) of the blades in fans with a double shaft is different, it is necessary to replace both impellers and balance the entire moving part.
  • Failure of valves and electromechanical components. Sometimes it is possible to change not the whole product, but only the drive or only the actuator.
  • Blockage or leakage in the hydraulics (both high pressure and in the drainage system). It is often more expedient to replace the entire assembly or section of the pipeline than to disassemble, clean and restore the tightness of old elements.

An important condition for a successful (cheaper, faster and better) repair is that the customer has all the documentation for the defective product and the HVAC system as a whole - both technical from the manufacturer and local, relating to a specific object - wiring diagrams, duct drawings, test records , commissioning, etc.

Service

Fancoil repair is closely related to its maintenance. On the one hand, during any repair, all preventive (routine) work is carried out along the way and, of course, are included in its cost, if there is no long-term contract for them, which we always recommend concluding.

On the other hand, high-quality and regular care significantly prolongs (often several times) the overhaul period. Not only the funds for the repair of the fan coil are saved, but the inevitable losses due to downtime are also reduced. After all, in some rooms, according to the norms of sanitary, technical or labor legislation, in principle, work (stay of people and / or functioning of certain systems) is not allowed without ventilation, cooling, dehumidification, heating and other air treatment.

In addition, many faults can lead to accidents that go beyond the devices in which they occur. Elimination of consequences is always more expensive than early prevention.

Our offer

Fancoil Motors allows you to order a fancoil repair in Moscow, carrying out, if necessary,

  • departure to the customer's site;
  • system diagnostics;
  • dismantling of damaged equipment, as well as related building and engineering structures;
  • supply of all spare parts and materials required for repair;
  • trouble-shooting;
  • related work on in-depth maintenance (regulation No. 2);
  • reverse mechanical and electrical installation;
  • construction (finishing) works - by agreement - to restore the integrity and aesthetics of the premises;
  • testing and commissioning with the preparation of the necessary documentation;
  • instructing the customer (personnel servicing and operating the system).

It is also possible to travel outside of Moscow, or vice versa, to repair the fan coil unit at a much lower price, provided that it is delivered by the customer to our workshop.

The main advantage of Fancoil Motors is the presence directly in the warehouse of a huge number of various components for HVAC systems - from electric motors and electronic components to consumables, which greatly speeds up repairs.